        E250 Heatsink Overtemperature Warning散熱器過(guò)熱警告。

        Description:說(shuō)明:

        The temperature of the heatsink in the drive controller has reached the

        maximum allowable temperature. Within a time frame of 30 seconds, the

        drive follows the command value input. Consequently, there exists the

        possibility to shut down the motor with the control so that it remains true to

        the process. (For example close the operation, leave the collision area,

        etc.) After 30 seconds, the parameter "Best Possible Deceleration, P-0-

        0119" set reaction appears during operation.


        驅動(dòng)器控制器中的散熱器溫度已達到最高允許溫度。在30秒內驅動(dòng)器遵循命令值輸入。因此,存在使用控制裝置關(guān)閉電機的可能性,使其保持正確這一過(guò)程。(例如,關(guān)閉操作,離開(kāi)碰撞區域,30秒后,參數“最佳可能減速,P-0-0119“設置反應在操作過(guò)程中出現。


        Cause:原因:

        1. Deficiency of the drive's internal blower.

        2. Deficiency of the control cabinet’s climate control.

        3. Incorrect control cabinet dimensioning regarding the

        head ventilation

        1.驅動(dòng)器內部鼓風(fēng)機不足。

        2.控制柜氣候控制不足。

        3.控制柜尺寸不正確頭部通風(fēng)

        8.29力士樂(lè )伺服驅動(dòng)器1.jpg


        Remedy:

        For 1. If the blower fails exchange the drive controller.

        For 2. Install climitization feature to the cabinet.

        For 3. Check the dimensions of the control cabinet.

        對于1。如果鼓風(fēng)機出現故障,更換驅動(dòng)控制器。

        對于2。為機柜安裝氣候調節功能。

        對于3。檢查控制柜的尺寸。


        F895 4 kHz Signal Error4 kHz信號錯誤。

        Description:

        The 4kHz signal is synchronized with the software processing for creation

        of the resolver signal. This error message is created when

        synchronization occurs improperly.

        4kHz信號與用于創(chuàng )建的軟件處理同步旋轉變壓器信號的。此錯誤消息是在以下情況下創(chuàng )建的同步發(fā)生不正確。


        Cause:

        1. The synchronization of the resolver controller voltage is invalid

        in regards to the software.

        2. The error can be produced through an electrical discharge.

        1.分解器控制器電壓同步無(wú)效關(guān)于軟件。

        2.該誤差可通過(guò)放電產(chǎn)生。


        Remedy:補救措施:

        For 1. Exchange drive controller and return for testing.

        For 2. Power down and then on. If this in not successful; exchange 

        drive controller.

        對于1。更換驅動(dòng)器控制器并返回測試。

        對于2。關(guān)閉電源,然后打開(kāi)。如果這不成功;交換驅動(dòng)控制器。

        在線(xiàn)咨詢(xún) 聯(lián)系方式 二維碼

        服務(wù)熱線(xiàn)

        021-50157782

        掃一掃,關(guān)注我們

        RM新时代官网网址|首入球时间
        <delect id="4fdos"></delect>

          <rt id="4fdos"></rt>

          <del id="4fdos"></del>
          <rp id="4fdos"><nobr id="4fdos"></nobr></rp>
            <rp id="4fdos"></rp>
            <tt id="4fdos"><form id="4fdos"><font id="4fdos"></font></form></tt>
              <delect id="4fdos"></delect>

                <rt id="4fdos"></rt>

                <del id="4fdos"></del>
                <rp id="4fdos"><nobr id="4fdos"></nobr></rp>
                  <rp id="4fdos"></rp>
                  <tt id="4fdos"><form id="4fdos"><font id="4fdos"></font></form></tt>
                    RM新时代app下载 新时代RM|APP官网网址 RM新时代新项目-百度知道 RM新时代正常可以出正常提 新时代平台